Przeglądanie stron 11
10
b. Select All devices on the local subnet if
you want Zone Message commands to be
sent to all players on your local network.
6. Change the default UDP Destination Port if
desired.
Note: All UDP ports for BrightSign players are set to
5000 by default. If you change the destination port for
this presentation, you will need to change the receiver
ports for all presentations linked to it.
7. Create a new presentation for the player(s) that
will be linked to the first player.
8. Add two media items of your choosing to an
interactive presentation (similar to the previous
example).
9. Click the Events tab under Media Library. Drag
and drop the Zone Message event onto the first
media item.
10. In the Specify zone message field, enter the
same command parameter that you used in Step
4.
Now, when you send a command to the first player using
the BrightSign App, it will send a similar command to the
other player(s) on the local network.
Creating User Variables
To modify User Variables in the BrightSign App, you
must first create them in a BrightAuthor presentation:
1. Go to File > Presentation Properties.
2. Navigate to the Variables tab and click the Add
Variable button.
3. Specify a Name for the variable. This will be
displayed above the value field in the BrightSign
App.
4. Select a Default Value for the User Variable.
5. (Optional) Check the Networked box if you want
the User Variable to also be updatable via RSS,
Live Text, or Dynamic Playlist (see the BrightAuthor
User Guide for more details).